Ultrasonic Flaw Detector NOVOTEST UD3701

The Ultrasonic Flaw Detector NOVOTEST UD3701 is designed to detect internal defects, such as discontinuities and heterogeneities of materials in products and welds, determine coordinates and evaluate defect parameters, measure thickness and the velocity of propagation and attenuation of ultrasonic waves in the materials (metals, plastics, glass and etc.), the search for places of corrosion, cracks, internal delamination and other defects.

Ultrasonic Flaw Detector NOVOTEST UD3701 is a universal, powerful, functional, ergonomic and reliable device for solving tasks of ultrasonic flaw detection both in the laboratory and in the field.

    • Superbright, touch display with which it is comfortable to work outdoors on a sunny day;
    • Automatic calculation of the delay in the probe;
    • Frequency range from 0 to 10 MHz, with smooth adjustment;
    • Display of a scale of scanning in microseconds and millimeters;
    • The presence in the device of the operating mode of the DAC and TVG curves (up to 16 points);
    • The presence in the flaw detector of the DGS control mode, with automatic calculation of the equivalent reflector zone;
    • Carrying out settings both using the touch screen and by keyboard;
    • The presence of movable blocks of output of measured values, so it can be located in any part of the A-scan;
    • Archive of measurements, settings, probes with the ability to transfer data to a PC;
    • Simulation of a measurement from a stored record in the device memory.
  • Operating frequency range from 1 to 10,0 MHz

    Range of measured time intervals (duration of scanning)from 6 to 1000 µs

    Velocity range1000 – 9999 m / s

    Error of measurement of time intervals not exceed ± 0,025 µs

    Maximum permissible error of measurement of the amplitudes of the signals at the receiver input in the range from 0 to 110 dB not exceed ± 0,5 dB

    Testing gain range125 dB

    Averaging over the quantity of starts from 1 to 16

    Range of variation of temporal sensitivity adjustment (TVG)40 dB

    Number of control points TVG16

    Duration of the excitation pulse to the load from 0,0 to 0,5 µs

    Deviation of the amplitudes of input signals in the range from 10 to 100% of the screen height not more than1 dB

    Setting a delay in the prism of the probe from 0 to 15 µs

    Detection of signals positive half-wave, radio mode

    Dimensions (W*H*L)140 mm x 210 mm x 55 mm

    Weight, not more1,5 kg

     
    • Additional UT-probes
    • Additional cables Lemo-Lemo
    • Charger
    • Bag for comfortable operating
    • Calibration blocks
    • Ultrasonic flaw detector
    • UT-probes – 2 pcs
    • Cable Lemo-Lemo – 1 pc
    • Charger
    • USB cable for PC connection
    • Operating manual
    • Case