Image | Part Number | Price | Variant | Purchase Quantity |
---|---|---|---|---|
4912100 | £310.00 | Vickers Test Block HV2 - We will contact you to discuss hardness value. | ||
4912200 | £310.00 | Vickers Test Block HV2.5 - We will contact you to discuss hardness value. | ||
4912300 | £310.00 | Vickers Test Block HV3 - We will contact you to discuss hardness value. | ||
4912400 | £310.00 | Vickers Test Block HV5 - We will contact you to discuss hardness value. | ||
4912500 | £310.00 | Vickers Test Block HV10 - We will contact you to discuss hardness value. | ||
4912600 | £310.00 | Vickers Test Block HV20 - We will contact you to discuss hardness value. | ||
4912700 | £310.00 | Vickers Test Block HV30 - We will contact you to discuss hardness value. | ||
4912800 | £310.00 | Vickers Test Block HV50 - We will contact you to discuss hardness value. | ||
4912900 | £310.00 | Vickers Test Block HV100 - We will contact you to discuss hardness value. | ||
4912110 | £310.00 | Vickers Test Block HV120 - We will contact you to discuss hardness value. |
Spectrographic
UKAS Certified Vickers Test Blocks
Test Blocks are set out in load, please add hardness value in comments at checkout. If you have any specific requires please contact the office.
Vickers hardness tester reference blocks are examined in calibrated laboratory and comply to the requirements of BS EN ISO 6507-3 2005 clause 3and ASTM E384-11 clause a2.3. Test blocks are calibrated on a standardising machine complying with the requirements of ASTM E384-11 clause A2.4 and BS EN ISO 6507-3 2005 having hardness scales traceable to UK national scales as defiled by NPL / PTB.
Hardness test blocks are only valid for the scale of which it was calibrated. It is recommended that the scale of validity should be limited to 5 years. For alloys of Al and Cu the validity should be restricted to 2 to 3 years.
Available in HV2 (ES10002-HV2), HV2.5 (ES10002-HV2.5), HV3 (ES10002-HV3), HV5 (ES10002-HV5), HV10 (ES10002-HV10), HV20 (ES10002-HV20), HV30 (Es10002-HV30) HV50 (ES10002-HV50), HV100 (ES10002-HV100), HV120 (ES10002-HV120).
- Test Blocks are set out in load, please add hardness value in comments at checkout. If you have any specific requires please contact the office. Vickers hardness tester reference blocks are examined in calibrated laboratory and comply to the requirements of BS EN ISO 6507-3 2005 clause 3and ASTM E384-11 clause a2.3. Test blocks are calibrated on a standardising machine complying with the requirements of ASTM E384-11 clause A2.4 and BS EN ISO 6507-3 2005 having hardness scales traceable to UK national scales as defiled by NPL / PTB. Hardness test blocks are only valid for the scale of which it was calibrated. It is recommended that the scale of validity should be limited to 5 years. For alloys of Al and Cu the validity should be restricted to 2 to 3 years. Available in HV2 (ES10002-HV2), HV2.5 (ES10002-HV2.5), HV3 (ES10002-HV3), HV5 (ES10002-HV5), HV10 (ES10002-HV10), HV20 (ES10002-HV20), HV30 (Es10002-HV30) HV50 (ES10002-HV50), HV100 (ES10002-HV100), HV120 (ES10002-HV120).